PSM-500/500L/500LT SCPC Satellite Modem Operation
PSM-500/500L/500LT - Rev. 0.91
.5 Sec
Numeric 0.0 to 600.0 seconds in 0.1
second increments.
Sets the minimum time that
a redundancy alarm must
last before switching occurs.
Idle
Selection Backup Status or Press “0”
or “Edit” then “Enter” to
transfer current
configuration to backup.
View status of or configure
backup. Only available when
on-line.
Mod & Demod
Selection 0 = Disable,
1 = Demod Only,
2 = Mod Only,
3 = Mod & Demod
Used to disable the Mod or
Demod and also the lamps
and indications when not
used.
Factory, 1 to 8
Selection/
Numeric
0 to 8, 0 = Factory Location to recover current
configuration from.
Factory, 1 to 8
Selection/
Numeric
1 to 8, Factory configuration
not alterable
Location to store current
configuration to.
After 1 Sec
Selection/
Numeric
Disabled (0), 1 to 14,400
seconds
Time after loss of rcv carrier
to restore this configuration.
…
Disabled
Selection/
Numeric
Disabled (0), 1 to 14,400
seconds
Time after loss of rcv carrier
to restore this configuration.
Last
Selection/
Numeric
Last (0), Recall 1 to 8 Behavior on power-up.
Either the last settings or try
to lock using one of the
stored configurations.
Full Access
Selection 0 = Disable,
1 = Read Only,
2 = Full Access
Keyboard access control.
Quick
Selection 0 = Quick,
1 = Edit Only
2 = Confirm
Keyboard Entry method.
Quick is the normal default
mode.
Backlight Full
Selection 0 = off, 1 = 1/3, 2 = 2/3, 3 =
Full
Active level of LCD backlight
Backlight 1/3
Selection 0 = off, 1 = 1/3, 2 = 2/3, 3 =
Full
Idle level of LCD backlight
Numeric 0 to 20 LCD Contrast setting
Beep
Selection 0 = None,
1 = Beep,
2 = Blink,
3 = Beep & Blink
Audible “click” and/or “Local”
LED Blink on front panel key
press.
Full Access
Selection 0 = Disable,
1 = Read Only,
2 = Full Access.
Remote control access
mode allowed