Datum Systems, Inc. PSM-500 Modem Remote Control Protocol
Rev 0.93 12/12/10
*If UpROM Enabled then Serial Number Confirmation Required else don’t care
[Modem3-Modem0] = Modem Self Test, 4b, 0=Normal, 1=Lamp Test, 2=Self Test, 3=Lamp & Self Test
[CalRef] = Reference Calibration, 1b, 0=Normal, 1=Enabled
[BootStat] = CPU Boot Status Code, 1b, 1=Reset Boot Code to Zero
Self Test Step Status
[Byte 28] Value: 1=Self Test Initializing, 2=Alarm On Test, 3=Upper Limit Test, 4=Lower Limit Test,
5=Loop Test 1 (4.92Mbps), 6=Loop Test 2 (2.4kbps), 100=Self Test Completed Successfully.
Self Test Status
Alm
Alm
Alm
Alm
Reference Calibration Status
[Bytes 34-35] Value: 1=Bad Input Reference, 2=DAC Error, 3=Flash Write Error, 4=Calibration Error,
5=Reference Calibration Completed Successfully.